[Back to Sensors List]
DT029 Temperature

Type:
Temperature
Thermistor NTC

Range:
-25°c - 110°c


Sensor Description:

The DT029 is a simple, durable, temperature sensor. It connects to the Data Logger using a standard mini-din cable. At the end of the sensor cable there is a temperature probe, covered with isolating material ensuring protection. The DT029 measures temperature between -25°c and 110°c, and has an accuracy of ±1°c. It is mostly suitable for water and other chemical solution temperature measurements.

How it works:

The DT029 connects directly to the Data Logger. At the other end of the cable there is a temperature probe. The temperature receives an input voltage of 5V and outputs a voltage between 0 - 5 Volts, which is the range accepted by the MultiLog analog-digital converter. The data logger then records the value into it's memory.

Calibration:

The DT029 is automatically calibrated. No further calibration is needed.

What is it used for:

The DT029 sensor can be used in various experiments such as endothermic reactions or the combined gas law. Also, the DT029 is recommended in long term measurements of bodies, water or outdoors temperature due to it's durability. The following graph is a measurement of the combined gas law experiment, performed using the DT029.

Specifications: